Wujiang Economic Development Zone Administrative Committee will set up a special helping to build group during the constructive process of a newly foreign-invested company in conformity with the spirit to serve the investors in one continuous line. This group will offer free services regarding information, getting programming allowance, construction allowance, etc. There are professional supervisors to supervise the quality and progress of the project. Construction and management procedures are as follows:
Construction project preparing phase
(1)
Select the site to make records
(2)
Examination and approval of Environmental Influence Form
|
¡ý
Verification of planning blueprint and approval for license of construction land planning |
¡ý
Verification of building blueprint and approval for license of construction land planning |
¡ý
Completion acceptance and approval for license of construction (temporary) |
¡ý
Pollutants declare and management of industrial production environment
(1)
Approval for license of emit pollutants
(2)
Management of industrial production environment protection
|
1. Water pollutants shall be carried out according to ¡°Sewage Multi-discharge Standard¡± (GB8970-1996), the discharge density standard value of the main pollutants is as follow:
Discharge Standard for Type I Pollutants |
Discharge Standard for Type II Pollutants (mg/l) |
Pollutant |
Discharge Density (mg/l) |
Discharge Density |
ClassI Standard |
ClassII Standard |
ClassIII Standard |
Otal Mercury |
0.05 |
PH |
6-9 |
6-9 |
6-9 |
Lkyl Mercury |
Not to be tested out |
Chromaticity |
50 |
80 |
|
Total Cadmium |
0.1 |
BoDS |
30 |
30 |
300 |
Total Chromium |
1.5 |
CoDer |
100 |
150 |
500 |
Six Valence Chromium |
0.5 |
Petroleum Oil |
10 |
10 |
30 |
Total Arsenic |
0.5 |
Volatile Phenol |
0.5 |
0.5 |
2.0 |
Total Lead |
1.0 |
Cyanide |
0.5 |
0.5 |
1.0 |
Total Nickel |
1.0 |
Copper |
0.5 |
1.0 |
2.0 |
In above table, Class I and II Standard of discharge standard for kind II pollutants are to be carried out according to the requirements of the functions for ground and water areas drawn by the Municipal People¡¯s Government, for the sewage discharged into urban sewers and into Grade II Sewage Factory to have Bio-treatment is to be carried out according to Class III Standard.
2. Air pollutants are to be carried out according to the Class III Standard in ¡°Multi-discharge Standard for Air Pollutant¡± (GB1629-1996), ¡°Discharge Standard for Industrial Furnaces & Kilns Air Pollutants¡± (GB9078-1996), etc. The following is the brief list for main pollutants discharge density standard value:
Pollutants |
Unit |
Boiler (65T/H) |
Furnace & Kiln |
Others |
Smoke |
Mg/Nm3 |
250 |
100 |
-- |
SO2 |
Mg/Nm3 |
1200 |
850 |
550 |
Blackness of smoke |
Ringelman degree |
1 |
1 |
-- |
Fluorine compound |
Mg/Nm3 |
-- |
6 |
9 |
Particulate |
Mg/Nm3 |
-- |
-- |
120 |
Lead |
Mg/Nm3 |
-- |
0.1 |
0.7 |
Hydrogen chloride |
Mg/Nm3 |
-- |
-- |
100 |
Sulfuric acid fog |
Mg/Nm3 |
-- |
-- |
45 |
Benzene |
Mg/Nm3 |
-- |
-- |
12 |
Nox |
Mg/Nm3 |
-- |
-- |
240 |
3. Noise shall be in accordance with ¡°Noise Standards for the Factory Boundary of Industrial Enterprises¡± (GB12348-90). The noise standard values of different factory boundaries are listed as follows:
Unit: LeqdB(A)
Kind |
Daylight |
Night |
Applicable Scope |
¢ñ |
55 |
45 |
area mainly for residence and cultural and educational organs |
¢ò |
60 |
50 |
residence, commerce, industry mixed area and commercial center area |
¢ó |
65 |
55 |
industrial area |
¢ô |
70 |
55 |
area along both sides of the main roads |
Each kind of standard is implemented according to the applicable scope drawn by the Municipal People¡¯s Government. |